Fix release date: 16 Jun 2017
Status: Superseded


Important: After installing this PTF, you will need a license key from your Blueworx sales representative or Blueworx support for BVR to continue taking calls. There is a grace period of 45 days in which to do this. Please see below for further details.


New feature contained in Fix Level 6.1.0.523:



New fixes contained in Fix Level 6.1.0.523:


Ticket#ProblemResolution
1186User receives an error that says: "Unable to read the list of data items Requested file not found." in the GUI. However, when the user calls into BVR, they are able to hear the voice segments.Increase limit on number of segments that can be viewed in the GUI.
N/AAMD ignores the initial voice_on_time worth of voice. This causes the AMD code to detect "human" with spoken audio longer than the human_time and shorter
than human_time + voice_on_time.
Use the current sample blocks length when moving from initial to detected voice states.
1244Double sending of RTP packets when performing a half tromboneAdd check to count number of outbound trombone legs present. If there is more than 0 then don't send on our own channel.


Download information


The PTF for this issue is available on the Blueworx FTP site:


https://blueworx.hostedftp.com/files/path/Fix+Center/BVR610/BVR.6.1.0.523.tar.Z


This PTF might require requisites PTF files to be installed and are available on our Blueworx FTP site in a cumulative collection of all Blueworx Voice Response fix updates from 6.1.0.500 - 6.1.0.519.


https://blueworx.hostedftp.com/files/path/Fix+Center/BVR610/BVR610.ML5.fix500-519.tar.Z