Fix release date: 05 Jul 2017
Status: Current
New fixes contained in Fix Level 4.2.0.161:
Ticket# | Problem | Resolution |
1089 | The IMC_SMDI_Client custom server, in addition to logging into IMC_SMDI_Client.log, is also logging to DTstatus.out and this causes unnecessary utilization of space and makes the DTstatus.out file unusable. | Modified IMC_SMDI_Client custom server so that it will write to DTstatus.out only when the LoggingLevel is greater than 3. |
1017 | MWI is not being sent for aliases upon message deletion and therefore it is possible it could be out-of-sync with the database. | The mwi_config command can now be used to verify triggers are working correctly with the -c option which must be followed by a test number. The mwi_config command also now supports the -C option to check that counts in the application profile table match those in the mailbox table and the -reset option to run a general reset on all message waiting indicators. For further details please use: mwi_config -h to see the new options and syntax. |
1195 | The moveprofile command has never had code added to support MR_SCHED table. | The IMC_MoveProfile custom server and the moveprofile command has been enhanced to also unload and load enhanced menu routing schedules for enhanced menu routing applications. |
1287 | Using the moveprofile -l on SurveyForms subscriber receives the message "Error: loading profile" due to the use of a semicolon in a database field (referral_number). | Fixed IMC_MoveProfile (via the moveprofile command) to support Survey mailboxes and the use of semicolon. |
Download Information
The Fix Level 4.2.0.161 is available on the Blueworx FTP site:
https://blueworx.hostedftp.com/files/path/Fix+Center/UM/dirTalk.UM.rte.4.2.0.161.bff